To commission the vesdae vea detector, you must have the necessary certification issued by xtralis or an authorized distributor. Where very early detection of smoke is an absolute necessity. Right detection for any application integrated emergency communications. Vesda early warning detectors are available in a variety of models to accommodate a broad range of environments and applications.
This document is intended for proficient installation engineers who are familiar with the commissioning of an mx fire detection system but have limited experience with the installation of vesda aspirating smoke detectors. Connects directly to the gamewellfci e3 series and s3 series fire alarm control panel. It suggests a maintenance schedule and provides instructions on how to service and maintain the different components making up a vesda laser system. This guide also assumes that you have an understanding of the various aspects of an aspirating smoke detection system and are fully aware of the local codes and standards. Air sampling pipe network calculations shall be provided by xtralis or a certified vesda distributor. All solvent cemented connections shall be assembled in accordance with. This guide is for the standard vesda product range only. There can be a maximum of 30 vesda units per interface card.
Available in two models, the vlf250 covers up to 250 square meters 2,500 square feet, and the vlf500 covers areas up to 500 square meters 5,000 square feet. The detector is shipped with the following components. Introduction to the vesda system design manual author. This shows an older device but its an excellent explanation of the mechanics. Vesda aspirating smoke detection is an early warning system that detects. Proper safety precautions must be taken during tests and. This guide is written for persons responsible for the maintenance of. For a larger standby capacity in a single vesdae vea installation or when more than one vesdae vea detector is to be powered, use model veabat battery enclosure to house up to two 12v 35ah or 36ah batteries or use a ul1481, ulcs527 or ul864 listed enclosure. This document is written to provide you with information on technical specifications, cabling, and how to install, configure and operate these detectors. For further information, please contact your local branch, and our staff will assist you. The detector chamber can detect presence of smoke at very low concentrations. A great classic video showing how a very early smoke detection apparatus works. Preinstallation checklist i have the appropriate mount to accommodate the roof pitch and my building structure. Specifications, images and particulars in relation to products are subject to change without prior notice and flamestop australia will not be held liable in.
These installation instructions provide essential information for installing vesdae vep aspirating smoke detectors in accordance with the system design. Intelligent vesdae vea slc addressable aspiration smoke detector supporting up to 36,000 sqft through 40 addressable detection points. Guide to trouble shooting faults on a vesda detector. M0158 06 laserscanner installation manual janus fire systems.
Vesda detection with fire suppression is a fantastic combination. Vesda aspirating smoke detectors buy the critical time needed to investigate an alarm and initiate an appropriate response to prevent injury, property damage or business disruption. The installation and programming of the asd shall be completed by a factory trained installer. Regional regulatory requirement and notices for the vesda. The vesda detectors are able to communicate this information to a fire alarm control panel, a software management system or a building management system via relays or a high level interface hli.
The vesda line of air sampling detectors is the most widely specified, installed, and has a proven track record of reliability. Vesda by xtralis vesda vlp product guide connecting the vesda vlp to the pipe network inlet pipes the inlets in the pipe inlet manifold are designed to receive a standard pipe of 25 mm 1 in od. Engineering specification guide vesdae vep notifier fire systems. Use the following point types for the following vesda systems. Notifier manufactures ewis systems, occupant warning and speakers. Guide to design pipe networks for the vesda detection system. Pipework installation manual, guide to installing pipework for vesda detectors. Vesda vlp product guide introduction the vesda vlp is an aspirating smoke detector providing very early warning of fire conditions by drawing air samples through an air sampling pipe network. Pn 3330803 v june 2009 aspirating smoke detection system limitations an aspirating smoke detection system which can be made up of smoke detectors, heat detectors, manual pull stations, notification appliances, and a fire alarm control unit with remotenotification capabilitycan provide early warning of a developing fire. Operation in normal operation, the vlc800mx is polled every 5 seconds for the current smoke read ing. Vesda vlc500 installation instructions pdf download. Our solutions will help you determine the best system to meet the needs of your application. Consult a structural engineer for mounting methods not covered in this manual.
Xtralis product specific manual included with the vesda equipment 41004120series vesda interface cards installation instructions, 574050 4100es operators manual, 579197 4010es operators manual, 579969 in this publication this publication discusses the following topics. Vesda by xtralis very early warning aspirating smoke detection solutions with continuous air sampling provide the earliest possible warning of an impending fire hazard. The vesda vlf is an aspirating smoke detector ideal for small, businesscritical spaces. These installation instructions provide essential information for installing vesda e veu aspirating smoke detectors in accordance with the system design. The system should not be connected to a power source until all. View online product manual for vesda vlp smoke alarm or simply click download button to examine the vesda vlp guidelines offline on your desktop or laptop computer. Intelligent vesdae vep aspirating smoke detectors are seamlessly integrated on the slc loop with notifier fire alarm control panels for a complete very early warning fire system intelligent vesdae vep brings the latest and most advanced detection technology forming the new aspirating smoke detection asd benchmark. Manual and product documents available from xtralis.
Very early smoke detection apparatus, vesda, air sampling, uk. Airintelligencetm asd640 aspirating smoke detection. Big ass fans can only be mounted to ibeams or angle iron. Xtralis accredited training course can install, test and maintain the system. Refer to the vsc documentation for details regarding the setting of these thresholds.
Installation instructions for vesda power supply model vps. Introduction to troubleshooting it is possible that occasionally a vesda laser system may indicate certain faults. This guide introduces you to the vesda vlc detector features and technical. The software is windows based and designed to be used by control center operators or fire protection companies supporting a site. These installation instructions provide essential information for installing vesda vlc aspirating smoke detectors in accordance with the system design. Xtralis vesda xtralis vesda vft15 product guide 1 introduction welcome to the xtralis vesda vft15 product guide. Installation instructions main sampling pipes 34 diameter shall be installed as follows. Notifier by honeywell is a manufacturer of fire protection products such as afp2800, afp3030 addressable fire alarm panels, smoke detectors and evacuation systems. Vesda system testing and commissioning method of statement. Refer to table 1, page 3 for power consumption details. These installation instructions provide essential information for installing vesda vlf aspirating smoke detectors in accordance with the system design. Faults not applicable to the standard vesda range of products have not been included in this guide. Ensure that all the precommissioning checks are carried out successfully.
Notifier also manufactures digital voice command for mass notification systems. European installations the product must use a power supply conforming to en54. Aspire2 is available from your vesda asd distributor. Vesda system configurator vsc the vesda system configurator is an optional tool that allows all vesda detectors to be configured. The xtralis vesda pipe network installation guide is written for those involved with the design specifications, management, installation and maintenance of an xtralis vesda system. This range can be used as an alternative to vlp and vlc products.
Vesda laser plus ve70d vesda laser scanner vscan mini vesda50 vmin50 note. The vesda system manager vsm4 software package sets up, monitors and troubleshoots vesda fire systems. Battery backup calculations the nominal supply voltage is 24 vdc. Please view our model comparison chart to determine which vesda model is. An automatic fire alarm systemtypically made up of smoke detec tors, heat detectors, manual pull stations, audible warning devices. All proper health and safety precautions must be taken during the installation, commissioning and maintenance of the product. Do not directly mount the fan to single purlins, trusses, or bar joists. A2 62612 fire alarm system limitations while a fire alarm system may lower insurance rates, it is not a substitute for fire insurance. Xtralis vesda vlc800mx installation, commissioning. It includes suggestions for a maintenance schedule and instructions on servicing the different xtralis vesda detector components. From small to very large, open spaces and from the cleanest to the dirtiest environments, vesda multilevel detection provides reliable, highsensitivity, very early warning smoke detection.
The optimum operation of an xtralis vesda system requires that the. It includes suggestions for a maintenance schedule and instructions on servicing an installed. This single, simple, easytouse tool is all you need to ensure that. Vesda addressing the vesda units address is obtained throug h the facp programmer when a vesda point is added to the job. Vesda vs spot smoke detection in high airflow environments duration. Vesda vlf250 and vlf500 installation instructions pertronic. The embedded and pc software complimenting the vesda vlp provides a wide. The system should not be connected to a power source until all the components have been installed. It is assumed that those using this guide will have knowledge of the local codes and standards. All parameters can be set manually or previously saved configuration settings may be applied. Use table 2 to calculate and to determine the battery backup requirements for your vesda system. Vesda detectors have multilevel warnings and a wide range of sensitivity where minute levels of smoke can be detected before a fire has time to escalate.